Since
1972
Protection Doesn't Cost ... It Pays !
. .. Ancient
Abyssinian Proverb
![]()
![]()
![]()
![]()
![]()
Frequently Asked Questions (FAQ) |
||
about
Radio Frequency Interference
|
||
with Frequently Given Answers |
The short answer is: from the same place that spikes/surges come from - Lightning, man-made electrical equipment noise and various transmitting equipment., Actually, Radio Frequency Interference is always associated with spikes and surges.
Lightning, the Mother of all Spikes, radiates radio energy across all bands from VLF to microwaves. Other weather conditions, known as spherics, also generate significant energy which often results in small electrical discharges, generating Radio Frequency Interference. While not as severe or dramatic as lightning, serious communication interference can result.
But there are other types of interference as well.
Radio stations, cellular phones, Citizen's Band and police radio, welding equipment, small office or household appliances, fluorescent lights, loose electrical connections, defective AC Power plugs, cords or sockets are among the many sources of electrical interference.
Interference is aptly named. The name came from the earliest days of radio when so-called static from various sources "interfered" with radio reception. This concept carried forward to television and ultimately to computers and other communication equipment.
Interference may cause erratic program operation; or it might cause errors in data processing (we've all heard the old anecdote of a $1,000,000 check being issued for a $1 refund).
In imaging - erratic, undesired color shifts might occur.
Communication may be disrupted or completely unintelligible.
Surveillance or Computer monitors may wiggle and sway - sometimes in step to the local rock and roll radio station down the street!!
Surveillance cameras and associated video monitors may show shadowy background patterns.
Audio systems may "play" local radio or TV programs. Other times the audio system may reproduce noise from fluorescent lights or diathermy equipment.
How can Radio Frequency Interference (RFI) be controlled?
Two approaches are usually taken for interference control.
1. Apply suitable preventative measures to the interference source. Of course, to accompolish this, the interference source must be identified. Even if identified, it is often impractical or impossible to taken corrective action. For instance - you can't do anything at the radio station.
For those noise sources that can be identified and accessed, a good first step is to ensure regular, thorough electrical maintenance of equipment suspected of being the interference source. Be certan all electrical connections are securely tightened.
When positive you have identified the interference source, install suitable filtering and suppression to bring interference under control. Very often a single socket (Industrial Grade) stand-alone power line filter-suppressor or a wire-in filter-suppressor solves the problem. Industrial equipment may require Twist-Type , Extreme Duty, or other Hi-Current filter-suppressors. Install filter-suppressors as close as possible to offending equipment.
While at the interference perpetrator, verify that all required grounding is in place and grounding screws are securely tightened. Since Radio Frequency Interference may emanate from many portions of the offending device, shielding efforts may be required in severe situations. Use great care to be sure any shielding installed is sturdy and safe. Also, be certain any installed shielding does not impede normal cooling air flow
2. Apply Radio Frequency Interference control steps at equipment suffering interference (victim). This is usually the route taken because it is often impossible to isolate or work on the suspected interference source.
Depending on the amount and severity of interference the equipment encounters, you could install an AC power line filter-suppressor, a KLEEN LINE® Regulator-Isolator-Conditioner or a KLEEN LINE® Isolation Transformer directly at the system. This is particularly effective if RFI is entering equipment over the power lines. Often, folding up the power line between equipment and filtering device will bring an added measure of relief.
Industrial equipment may require Twist-Type or Hi-Current filter suppressors.
Should further relief be required, investigation should turn to cables entering the affected equipment. Speaker or pre-amp cables in audio systems; incoming signal cables in remote terminal monitors; data line or network connecting cables; phone lines; street cable in cable tv units
3. Modem interference originating over Phone lines is discussed in our Modem & Phone section. Models generally used to provide interference relief for phone line connected modems or other equipment are PDS-11 and TURBO. These units have integral RFI filtering networks, very effectively isolating affected equipment from the attacking RFI energy. In addition to effective RFI filtering, these units very High Performance Spike Suppression systems, providing total equipment protection.
Severe Modem and Phone interference has successfully been countered by installation of our TURBO-MAX on incoming phone lines.
Direct wire or Din rail versions of these models are available
4.RFI interference control is discussed in our Network & DataLine page, on our Security / Surveillance page and on the Video page. A wide array of products are presented for RS-232, RS-485, RS-422, 10Base-T, 100Base-T, Ethernet, video, camera and phone lines. Although most units shown in the network and data line sections are protectors only, Electronic Specialists has been successful in applying RFI reduction techniques to all areas of communication, computing and surveillance equipment. Contact our Engineers for help with your RFI problems
5. Video terminal, cable TV, Satellite receivers and computer monitor interference is discussed on the Video page. Solutions for many problems are offered.
Visit our Extensive Application Note Section
ezine Editors <> Permission is hereby
granted to use any of these copyright protected
Hi-Tech FAQ's in your ezine. Source Credit and hyperlink are
required
Thank You for visiting the Electronic Specialists Web Site
<e-mail> to request FREE catalog
Also Available
Complete line of modem & phone protection systems in
solder terminal or screw terminal configurations
Special design modem / phone / data configurations for
telecommunications or data communications
Other plug / jack / voltage configurations
Multiple circuits in single case
View a few or our many available designs
Contact us with your special requirements

<> <> <> <>
Electronic Specialists
designs and manufactures a complete line of
Hi-Tech protective and interference control equipment
<> <> <> <>
We ask you to consider
Electronic Specialists Professionally
Engineered products for .....
. . . . office network, intranet, communication and sound
systems
. . . . factory computerized production equipment and
automated machinery
. . . . your home computer, modem, phones and
entertainment center
Visit our other great Product Protection
Departments........
View High Performance protection
solutions for your factory / office / home
|
Ferroresonant Voltage Regulators Precision Variac Voltage Regulators ....... Stepper Motor Voltage Regulators ......Hi-Power Voltage Regulators |
Modem
Speed-up & Telecommunications Protection Systems RJ-11, RJ11, RJ-21, RJ21, RJ-45, RJ45 Screw Terminals <> Wire-In <> DSL |
Cable
Modems W-4b Speed-up, Isolation, Intermittent Cable Sync Fix, & Protectors Systems |
|
Voltage
Regulation extends UPS operating Voltage Range
|
Software Books .... Technical, Computer |
Networks,
Data Line , Controller Protection RS-232, RS232, RS-422, RS422, RS-485, RS485 DB-9, DB9, DB-15, DB15, DB-25, DB25, Wire-in RJ-11, RJ11, RJ-45, RJ45, 10Base-T, 100Base-T Automation, Instrumentation Protectors |
| AC Power
Protection ...... Discussion & Over View |
Multiple
circuit Relay Rack Mount Modem / Phone / Telco Protection |
Networks, Data Line, Controller Banks Relay Rack Mount--Multiple Line Systems Process Control and Automation |
|
AC Power Line
Protection 220-250 Volts ...... Commercial ... Industrial and .. Laboratory & Basic Grades NEMA 6-15, 615, 6-20, 620 |
Direct Plug
AC Power Protection with built in Modem Protector
Dual Function
- Direct Plug AC Power |
Dual Function
- Direct Plug AC Power and Network Protectors |
|
AC Power Line
Protection <> 120 Volts ...... Commercial ... Industrial and .. Laboratory Grades International too ! NEMA 5-15, 515, 5-20, 520, 6-15, 615, 6-20, 620 |
Phone System
Protection and Interference Control Modular plugs, sockets RJ-11, RJ11, RJ-21, RJ21, RJ-45, RJ45 |
Audio-Video
System Protection Cameras, Monitors, Displays, Amplifiers 50 / 75 ohm, RG-6, RG6, RG-58, RG58, RG-59 RG59, RG-62, RG62, RCA, PL-259, BNC, UHF Video Guard Hum Buckers |
| Wire-in AC Power Line Filter-Suppressors Wire Leads <> Screw Terminals Solder Lugs <> Push-on Tabs Retrofit and OEM applications |
DIN
RAIL Mount Modem - Phone Line Protectors NetWorks Protectors RJ-11, RJ11, RJ-21, RJ21, RJ-45, RJ45 DB-9, DB9, DB-15, DB15, DB-25, DB25 Screw Terminals <> Wire-In |
Video <> Monitors & Displays
<> Surveillance Video Interference Choke Video Guard Hum Buckers |
| Extreme Duty Motor and Controller Suppressors single phase <> 2-phase <> 3-phase |
Twist-Lock® * Filter-Suppressors for NEMA L5-15, L5-20, L5-30, L515, L520, L530 L6-15, L6-20, L6-30, L615, L620, L630 L10-, L11-, L14-, L15-, 15, 20, 30 * Twist-Lock is a registered trademark of Hubbell Incorporated |
Relay Rack
Mount, Multiple Circuit Video Protectors |
| Variable
Voltage ....... Regulators ....... Isolation Transformers ....... Variacs ....... 400 Hz Variacs |
Industrial
& Copier Hi-Current Filter-Suppressors AC Hi Power Protection NEMA 14-20, 1420, 14-30, 1430, 14-50, 1450 |
Cable
Modem <> Speed-up, Isolation & Protection System |
| Ground Loop
Control ...... Voltage Regulators ...... Isolation Transformers ...... Cable TV / Cable Modem Isolators |
Application
Notes ...... Dozens of Practical Money Saving Tips |
Cable
Isolators Audio/Video Ground Loop Eliminator F-connector <> BNC-Video Guard |
| Isolation Devices ....... Transformers ....... Isolators-Filters |
Pneumatic
Interrupters * Power Shutdown Pressure <> Vacuum Switches |
Surveillance
<> Security Monitors / Displays / Video Protectors Video Guard Hum Buckers |
| New ! ! AC Power Line Interrupters
Power Shut Down |
Power
Transformers ...... Regulators ...... Isolation ...... Autotransformer |
Power
Conditioners ...... Regulators ...... Isolation Transformers |
| New ! ! AC Power Line ,,,,, Voltage Converters ,..., Voltage Converter Regulators ..... Voltage Converter Plug Adapter Strips ..... Universal AC Plug Adapters |
Travel Adapters .... Phone RJ-11 Adapters .... AC Power Plug Adapter Strips .... AC Power Plug Adapters |
Lap
Tops ..... Laptop Phone Line Protector ..... Laptop AC Power Protector |
| Variable / Adjustable
Transformers ....... Variacs ....... 3-Phase Variable Transformers ....... 400 Hz Variacs ....... 400 / 60 / 50Hz Variable Transformers ....... Stepper Motor Voltage Regulators |
View Custom Design Transformers |
Application
Guide Cross Reference Locate Your Problem - - - - Find a Fix !! We Now Offer Software Check 1,000's of Books |
| NEW ! ! ....... Rotary Converters ....... Frequency Converters |
NEW ! ! Satellite Protection Systems & Power Supplies * Industrial * Commercial | Complete Subject and Product Listing |
| SureTest
Electrical Circuit Analyzer <> Harmonics <> Ground Voltage & Noise <> Load Voltage Drop <> Ground Impedance |
Can't Find What You
Need ? Look Here ! or Check our Search Engine |
Why
the Professionals buy Electronic Specialists Protection Products |
| Complete Subject and Product Listing |
Free Tutorial - Equipment Protection | Complete Product index |
| Press Releases | Check Out - - - - Free Stuff | Product Application Notes |
| Check out complete Site Map |
Learn
What "Everybody " Knows - - - - or should Know ! ! |
Why you need Hi-Performance Protection |
| Save !! Surplus from Production |
Electronic
Specialists Home Page |
About Electronic Specialists |
| Frequently
Asked Questions <> with dozens of Answers |
|
Check our Search Engine |
Electronic Specialists
regularly supplies Regulation, Suppression and Protection Products
for 100, 110, 115, 117, 120, 125/250, 120/208, 220/380, 277/480 Volts
single, dual and 3-phase systems
![]()
FREE Tutorial
($400 Value)
Industrial Electronics - - - - - - Friend or Foe ??
We reveal why your Hi Tech Stuff sometimes becomes downright unfriendly --
and what you can do about it
Discover How to Get Maximum Performance from Your System
Sign Up Today
Learn Secrets the Pros use to Get Maximum Performance from Your System
A New, Free Performance boosting Tutorial segment will follow every few weeks
|
Why Sign Up
for
Free Tutorial?
Click Here for our 30 Second Pitch
|
![]()
FREE ! !
Newsletter
Why Should You get our Free Newsletter ????
Because . . . . . .
We Answer Your Questions !
We Offer You Equipment Protection Tips !
We Inform You of
New Products !
We Give You Special Newsletter Discounts !
![]()
View a recent copy of our Newsletter
![]()
Please Recommend us to an Associate or Friend ....Click Here
. . . Thank You
!
![]()
Click Here for some interesting FREE Deals, Techie Stuff and Other Offers
![]()
Custom Engineered Designs - OUR SPECIALTY
ORDER DESK
30 Day Money Back Guarantee - - Satisfaction - Or Your Money Refunded
![]()
Secure
Order Form
We accept . . . . Visa <> Discover <> American Express <> MasterCard
Prefer Fax or e-mail ? ........ Print out Order Form
You ask "Who buys Electronic Specialists Protectors?"
- -
Check
These organizations are protecting their systems - - Shouldn't You ? ?
![]()
Can't Find
Item You Need? Do a Search . . .
or
![]()
For Phone Order ..... or to Request
Free
Catalog Disc <> Free Technical Assistance
<>Free Custom Design Assistance
e-mail
<> FAX 1-508-653-0268
<> Phone 1-508-655-1532
<> Toll Free (U.S.)1-800-225-4876
![]()
Reseller, Dealer & Industrial Inquiries Welcome <e-mail>
Volume Discount
Privacy Policy
Electronic Specialists will never provide your name or e-mail address to a third party
RETURN TO .....
..... Electronic Specialists HOME PAGE
SITE MAP
©
1996 - 2004 Electronic Specialists, Inc., 75 Middlesex
Avenue, PO Box 389
Natick, Massachusetts 01760; All Rights Reserved
![]()